Sign In | Join Free | My burrillandco.com
Home > Clean Room Hepa Filter Box >

H14 Efficiency Clean Room Hepa Filter Box With Independent Fan 660*660*500mm

Hongkong Yaning Purification industrial Co.,Limited
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap H14 Efficiency Clean Room Hepa Filter Box With Independent Fan 660*660*500mm from wholesalers
     
    Buy cheap H14 Efficiency Clean Room Hepa Filter Box With Independent Fan 660*660*500mm from wholesalers
    • Buy cheap H14 Efficiency Clean Room Hepa Filter Box With Independent Fan 660*660*500mm from wholesalers
    • Buy cheap H14 Efficiency Clean Room Hepa Filter Box With Independent Fan 660*660*500mm from wholesalers
    • Buy cheap H14 Efficiency Clean Room Hepa Filter Box With Independent Fan 660*660*500mm from wholesalers

    H14 Efficiency Clean Room Hepa Filter Box With Independent Fan 660*660*500mm

    Ask Lasest Price
    Brand Name : YN
    Model Number : YN-BFU-610
    Certification : CE/ISO
    Price : reconsideration
    Payment Terms : L/C, D/A, T/T, Western Union
    Supply Ability : 10000pcs/month
    Delivery Time : 7-15 work days
    • Product Details
    • Company Profile

    H14 Efficiency Clean Room Hepa Filter Box With Independent Fan 660*660*500mm

    Terminal hepa filter unit hepa box with independent fan for clean room


    1. Terminal hepa filter unit description

    The BFU terminal hepa filter unit, which uses the latest technology in the United States, is a ceiling unit with a fan inside, used for turbulent flow and laminar flow clean room. BFU fan filter unit is one of the quietest and best-priced units on the market.


    FFU is an abbreviation for English, the full name is Fan Filter Units, which means "fan filter unit (unit)". That is, a fan and a filter (HEPA) or Ultra High Efficiency Filter (ULPA) are combined to form a self-powered end purification device. Specifically, it is a self-contained, modular end air supply with filtering efficiency. The fan draws in air from the top of the FFU and filters it through HEPA. The filtered clean air is evenly sent out over the entire wind surface at a wind speed of 0.45 m/s ± 20%.


    2. Terminal hepa filter unit advantages

    1), lightweight module structure design, suitable for the installation of the ceiling keel (T-Grid) system of each manufacturer;
    2), with dual overload protection high-performance motor, high static pressure, low noise, low energy consumption, can save operating costs;
    3), low noise, the source of scientific motor and wind guiding structure design, so that the noise level of the product is lower than similar products;
    4), the air is even, the wind pressure spreads evenly to meet the requirements of the international standard IES-RP-CC002 +/- 20%;
    5), low fretting, the total vibration rate is less than 1mm / s, the amplitude does not exceed 3um;
    6), flexible control mode, can be used for single-speed, three-stage speed regulation, five-stage speed regulation or stepless speed regulation to adjust air volume and with operation/abnormal indicator/abnormal dry contact for easy monitoring;
    7), can be customized for a variety of special specifications;
    8), pre-filter (G3-G4) and chemical molecular filter can be added as needed.

    9), can install abnormal indoor fault LED lights;
    10), can be installed with differential pressure gauge, wind speed sensor, etc.;
    11), can be installed with a small 99 monitoring system or a large remote central monitoring system.


    FFU / BFU Standard type

    • The degree of cleanliness from class 1 up to 100,000 can be set and it can be set at individual area.
    • Because the back in the ceiling is a low-pressure area, the potential of the leakage is extremely low.
    • Bay method or through the wall method is possible by the arrangement of the layout of FFU.
    • The volume of the air flow can be set at each area.
    • Flexible increase or change of the clean room is possible by the arrangement of Fan Filter Unit.

    3. FFU / BFU Parameter

    ModelFFU/BFU-YN920FFU/BFU-YN1175FFU/BFU-YN1225Unit
    Size920×615×3501175×575×3501225×615×350mm
    plenum chamber materialsAluminized zinc plate/stainless steel.Aluminized zinc plate/stainless steel.Aluminized zinc plate/stainless steel.
    Air flow80010001200m3/h
    Average wind velocity0.4/0.45/0.50.4/0.45/0.5/0.4/0.45/0.5m/s
    Extemal static pressure97(10mmAq)97(10mmAq)97(10mmAq)pa
    Hepa filter size915×610×691170×570×691220×610×69mm
    Efficiency0.12um@99.99%0.12um@99.99%0.12um@99.99%
    Filter initial pressure loss180Pa@0.45m/s180Pa@0.45m/s180Pa@0.45m/s
    Power180Pa@0.45m/s180Pa@0.45m/s180Pa@0.45m/s
    Fan vibration coefficient0.2-0.5mm/s0.2-0.5mm/s0.2-0.5mm/s
    Power dissipation123123172W
    Weight242831Kg
    Noise535555dB

    Quality H14 Efficiency Clean Room Hepa Filter Box With Independent Fan 660*660*500mm for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Hongkong Yaning Purification industrial Co.,Limited
    *Subject:
    *Message:
    Characters Remaining: (0/3000)