Sign In | Join Free | My burrillandco.com
Home > FFU Fan Filter Unit >

2'' X 2'' HEPA Filter Laminar Flow Hood FFU Fan Filter Unit For Clean Room / Mushroom

Hongkong Yaning Purification industrial Co.,Limited
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap 2'' X 2'' HEPA Filter Laminar Flow Hood FFU Fan Filter Unit For Clean Room / Mushroom from wholesalers
     
    Buy cheap 2'' X 2'' HEPA Filter Laminar Flow Hood FFU Fan Filter Unit For Clean Room / Mushroom from wholesalers
    • Buy cheap 2'' X 2'' HEPA Filter Laminar Flow Hood FFU Fan Filter Unit For Clean Room / Mushroom from wholesalers
    • Buy cheap 2'' X 2'' HEPA Filter Laminar Flow Hood FFU Fan Filter Unit For Clean Room / Mushroom from wholesalers
    • Buy cheap 2'' X 2'' HEPA Filter Laminar Flow Hood FFU Fan Filter Unit For Clean Room / Mushroom from wholesalers
    • Buy cheap 2'' X 2'' HEPA Filter Laminar Flow Hood FFU Fan Filter Unit For Clean Room / Mushroom from wholesalers
    • Buy cheap 2'' X 2'' HEPA Filter Laminar Flow Hood FFU Fan Filter Unit For Clean Room / Mushroom from wholesalers
    • Buy cheap 2'' X 2'' HEPA Filter Laminar Flow Hood FFU Fan Filter Unit For Clean Room / Mushroom from wholesalers

    2'' X 2'' HEPA Filter Laminar Flow Hood FFU Fan Filter Unit For Clean Room / Mushroom

    Ask Lasest Price
    Brand Name : YN
    Model Number : YN-FFU
    Certification : CE ISO GMP
    Price : US$130~200/PCS
    Supply Ability : 200 per week
    Delivery Time : 7-15 working days
    • Product Details
    • Company Profile

    2'' X 2'' HEPA Filter Laminar Flow Hood FFU Fan Filter Unit For Clean Room / Mushroom

    2'' X 2'' HEPA Filter Laminar Flow Hood FFU Fan Filter Unit For Clean Room / Mushroom

    What are Fan Filter Units and how are they constructed?

    Since the mid-1980s, Fan-Filter-Modules have been available on the market under the term FFU, which stands for Fan-Filter-Unit and

    represents a compact unit for the generation of high-purity air. These units made it possible for the first time to bring greater flexibility

    into the air flow in cleanrooms. The possibility of controlling the modules individually made it possible to flexibly vary the air discharge

    velocities under the filters within a room. It was no longer necessary to use filters with different pleat heights and thus variable differential

    pressures, which was also a rigid and not a flexible system.

    At that time, these first units were mainly available in a few standard sizes, which were mainly oriented to the outer dimensions of 300,

    400, 600, 900 and 1,200 mm. When used in various cleanroom ceiling grids, these dimensions could deviate downwards to reach ceiling

    grid dimensions of 600, 900 and 1,200 mm. These, however, quite limited dimensions reduced the use mostly only to cleanroom ceilings

    and cleanroom cabins.

    190325-ffu-overview

    Since then, the development of Fan-Filter-Modules has experienced a strong upswing. There are many suppliers worldwide whose units differ in details or even fundamentally from those of other suppliers.

    In addition, the usage possibilities have expanded to other areas such as minienvironments, glove boxes and mobile systems. The field of (customer) machine-integrated solutions has also developed strongly.

    At this point, we would like to discuss some designs that deviate completely from the basic design. Standard dimensions, which are limited to a few dimensions in length x width, are no longer an issue.


    Product Detail:


    Feature:
    1. With high performance, ultra-slim design, and proven performance,air velocity of the filter is made more even.
    2. The cabinet is made of cold-rolled steel plate sprayed or made of stainless steel, compact structure and beautiful appearance
    3. Using direct-drive high efficiency centrifugal fan(with a noise level of 56 db), with low noise, small vibration and long life, maintenance-free.
    4. Various controllers can be applied (On/Off, 3 Step etc.)
    5. With Differential Pressure Buzzer / Filter Replacement Alarm to indicate the time to replace HEPA filter.

    Technical Parameters:

    FeatureSpecification
    Control SystemAC single 3 stage control, EC Group Control
    VoltageAC 1N, 110V,220V/50,60HZ
    MaterialAluminum, Galvanized Plate, Stainless Steel, Powder Coating Steel
    Dimension575*575*300mm
    Air Flow500m3/h
    Noise Level52-62dB(A)
    Filter Efficiency99.95%
    ApplicationBiophramaceutical, Optical Electronics, Semiconductors, Aerospace, Hosptials, Food Processing, Spraying
    PrefilterG4 pleated panel filter
    Filter Size570*570*69mm

    Applications:


    Generally, clean room systems include air duct systems, FFU systems and axial flow fan systems. Clean rooms with a cleanliness level of 1000 (FS209E standard) or ISO 6 or above usually adopt FFU layout, partially purified environment or clean cabinet , clean workbench, etc. are usually implemented using FFU. Because compared to duct systems, FFU has the following advantages:


    1.Replacement, installation, and movement are flexible and easy. FFU is self-powered and self-contained and modular. The supporting filter is easy to replace, so it is not restricted by area. In clean factory, it can be controlled by zone,replaced as neededand move.


    2.Negative pressure ventilation is a unique feature of FFU. Because it can provide static pressure itself, the clean room is at a positive pressure relative to the outside world. In this way, external particles will not leak into the clean area, making sealing simple and safe.


    3.Shorten the construction period. Using FFU eliminates the need for making and installing air ducts, shortening the construction period.


    4.Reduce operating costs. Although the initial investment when choosing FFU is higher than using duct ventilation, it has outstanding features such as energy saving and maintenance-free in later operations.


    5.Space saving. Compared with other systems, the FFU system occupies less floor height in the air supply static plenum box and takes up basically no clean indoor space.

    Dongguan Yaning Purification Equipment Co., Ltd

    YANING was established in 2011, located in Dongguan City, Guangdong. We are a professional manufacturer of air purification equipment as well as purification project solution provider, also an ISO 9001 national certified high-tech enterprise.
    We have more than 100 models covers several major categories including modular clean room, cleanroom equipment like cleanroom air shower for person & cargo, cleanroom pass box, clean bench, FFU fan filter unit, laminar air flow ceiling etc.; modular operating room, operating room wall panel, stainless steel hand wash sink, stainless steel cabinet etc.; Air filter ranged from primary level to medium and high efficiency level such as plate pre filter, bag medium filter, v-bank hepa filter, etc. Our products have been widely used in hospital, health care, electronics, food processing, precise instruments, aerospace, automobile manufacturing industry and so on.
    Welcome to inquire any products or services at any time!

    FAQ:

    1. Are you a trading company or a manufacturer?

    We are a professional manufacturer for over 13 years with more then 10 years exporting experience.

    2. What can you buy from us?
    1) Modular clean room&clean room equipment like cleanroom air shower, cleanroom pass box, FFU Fan filter Unit, BFU, laminar flow ceiling, Clean Bench, Clean Booth, etc
    2) Hospital Operating Room Supporting Equipment, like modular operating room, operating room wall panel, stainless steel cabinets, Laminar Flow Ceiling, Socket box for OT room, OT room intelligence Panel, stainless steel hand wash sink, all kinds of hermetic doors, operating room etc
    3) Air Filter, such as Plate pre filter, F5-F9 Medium Pocket Filter, V-bank hepa Filter, Pleated HEPA Filter, Activated carbon filter, Gel Seal HEPA Filter, and High Temperature Resistant HEPA Filter etc.
    4) Air Conditioning and Ventilation Terminal Equipment: Air Vent Louver Grille Series and Regulating Valve and Fire Damper

    3.How long does your delivery time?
    Within 15 days for one 20ft container.it will depend on the quantity.

    4.Do you provide samples?
    Yes,we accept free sample for some models, but the customer should be pay the shipment costs.
    There will be sample cost for some models, but it can be refund after order placed for same models

    5.What's your payment terms?
    1).We accept the small order payment route by T/T, MoneyGram,Credit Card,Paypal,West Union,Cash,Escrow,Letter in Credit at sight.
    we also accept the Payment funds such as USD, EUR, HKD,CNY.
    2).Usually, 50% deposit after PI confirmed and balance 50% should be paid before shipment.
    if the order's total amount below $5000, It should be paid 100% in advance.
    3).We also accept the Letter of Credit at sight

    6. Are you an OEM production factory?
    Yes,welcome OEM order,we accept customized order.

    7.What's your package?
    1)Plastic bag 2)Bubble film 3)Carton,plywood case 4)Pallet or according to your requirements

    8.How to provide the royal quality?
    1) We Always make a pre-production sample before mass production;
    2) After 4 times quality levels treatment go though final Inspection before shipment.
    3)Matched ISO14001,ISO9001,TUV,ROHS.CE,UL etc. certificate.

    9.Accepted Delivery Terms: FOB, CFR, CIF, EXW, Air or Express Delivery;
    Quality 2'' X 2'' HEPA Filter Laminar Flow Hood FFU Fan Filter Unit For Clean Room / Mushroom for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Hongkong Yaning Purification industrial Co.,Limited
    *Subject:
    *Message:
    Characters Remaining: (0/3000)